Composite roof sheets installed as part of a refurbishment during 2022:
- Main fixings to sheets are missing, not installed to manufacturer’s recommendations or industry standards.
- Main fixings and side lap screws are over tightened, loose, and starting to protrude out.
- End lap and side lap sealant is not in place; therefore, water may penetrate through laps.